Pump room temperature maintained at least 40 degrees fahrenheit. The devices within a fire pump controller panel perform such functions as receiving signals from alarm devices, such. The auxiliary jockey pump controller, if required and specified on the plans and specifications, shall be factory assembled, wired, and tested and specifically designed for this type of service. Know how to design fire pump piping to meet nfpa 20 requirements. It ensures that the pump operates when called to start. The pump shall be hydrostatically tested and run tested prior to shipment. Only the highest quality components are used throughout our controllers to assure the best possible reliability. We serve the worldwide market covering commercial, residential, industrial premises and also. Manual for model fd4 fire pump controllers starting serial no. Appreciate cost variations between different pump styles and controller. Fire pump controllers can be divided into diesel and electric firepump controllers, and since firepump controllers are always specific to only one firepump theyre never combined. So how can choosing the right fire pump controller help you. A typical fire pump installation includes several components.
The pump controller monitors the pressure in the fire protection system, starts and stops the pump, reports problems, and sends alarm signals. Controllers are listed by underwriters laboratories, inc. When the controller is actuated by the pressure switch, start pushbutton. Provides technical information related to the installation of electric fire pump controllers. Fire pump controllers transfer switch controllers g4 innovation. Controls level of conductive liquids in pump up fill or pump down drain applications. Includes controller, vm multistage pump, flow switch isolation valves, 24 litre high pressure supercell tank and stainless steel manifold, all mounted on a stainless. There are many considerations that go into designing a building, and all of these decisions cost time and money. The very first choice you should consider is whether or not your building is suitable for variable speed. Hello friends, today in this video i have shown how to make a simple automatic water pump controller circuit. Controllers shall be equipped with contacts open or closed to operate circuits for the conditions in 10. Understanding fire pump controller applications fire pump controllers are control panels containing electrical components such as circuit breaker, switches, relays and other devices dedicated to the operation of fire pumps. Reverse phase light off or normal phase pilot light on. Fire pump controllers houston, tx flowtech industries.
Electric fire pump controllers lxi 1700 controller pdf manual download. Fd4e standard nema 2 fm approved, ul listed since 1970, metron eledyne has been a leading global supplier of fire pump control systems, custom control products, and specialised electrical and electronic solutions. Protects submersible pumps against dry running and prevents overfilling. May 17, 2017 does the nfpa require the fire pump controller to be a ul listed. We decided to use the intelidrive lite fpc for our fire pump system, due to the many advantages the controller provided. Flowtech industries, inc specializes in the conception and manufacturing of fire pump controllers listed by ul and approved by fm and in accordance with the widely recognized nfpa 20 standard. The signals you mentioned are only required to be separate in the engines controller, which is always in the fire pump room. It initiates a weekly program test of the system and records analog water pressure measurements. They are designed to control and monitor the fire pumps, fulfilling the requirements described by the firepump controller standards. Pump controllers are intended for use with electric.
Hubbell electric fire pump controllers lxi 1700 specifications. View detailed import data, price, monthly trends, major importing countries, major ports of fire pump control under hs code 84. As29412008 requirements a fire pump controller must start the fire pump in response to an external starting signal which is normally pressuresetting of a. The pump shall be hydrostatically tested at a pressure of not less than one and onehalf times the. Automatic metron fire pump controllers conform to the latest requirements of chapter 7, national fire protection association pamphlet 20, standard for. The lmr controller has a common alarm relay which energizes whenever there are any alarm conditions present. This controller shall be ul listed, and shall be of the same manufacturer as the main fire pump control ler. Comap intelidrive fire pump controller engine controller. View and download hubbell electric fire pump controllers lxi 1700 specifications online. Lmr electric fire pump controllers features 12 fd80 reduced voltage wye delta stardelta closed transition february 2005. Description all fire pump controllers are factory assembled, wired, tested as a unit and confirmed to all requirements of the latest edition of nfpa20 centrifugal fire pumps and nfpa70 national electrical code. The nfpa 20 fire pump controller automatically starts the diesel engine from water pressure control or nonautomatically from manual electric control. Ff this manual provides general information, installation, operation, maintenance and system setup information for metron model fd4 engine driven fire pump controllers. The location for a diesel engine driven pump may be dictated by the requirement for an air supply and the need to vent the exhaust.
Find all fire pump controller drawings as well as jockey pump controller, remote alarm panel, and low suction shutdown controller drawings here. The intelidrive lite fpc is very friendly and easy to use, allowing for easy use and simple adaptation. The control system then varies the pump speed depending on the actual suction pressure and. Nfpa 20 fire pump controller generator controllers. Intended for use by specifiers, purchasers, installers and owners of fire pump controllers. This controller provides automatic cycled cranking, alarm andor alarm shutdown protection for various engine failures. The nfpa 20 fire pump controller features rs232 and rs485 serial interfaces. This relay is energized under normal conditions and has led status indication on the main relay board. Technology backed up by a traditional fire pump controller master ecv and ecvt variable speed controllers combine the reliability of the ec series. With over 30 years of experience is proud to be the premier supplier of fire pump products in the united states. Power to the pump by mike holt, nec consultant why some fire pump requirements are backward one of the principal nec requirements for circuit protection is that you shut down the equipment rather than let supply conductors melt from overload. The fire pump controller is arguably the most critical and essential component in the fire pump assembly. Nov 02, 2016 in the latest version on nfpa 20 2016 remote indication is required when the pump room is not constantly attended.
A wide variety of fire pump controllers options are available to you, such as low pressure. Controller residential fire pump circuit breaker disconnecting means residential electric fire pump controller operating instructions totakeoutofservice pump controller fdr residential fire pump controllers features 12 fdr residential simplex, duplex july 2006 dimensions n. Fire pump controller for electric motor driven fire pumps m300 fire pump controller across the line types series m300. Import data and price of fire pump control under hs code 84. I believe the reason is not required to be separate in the remote indicator panels is to force personnel to go the fire pum. Combined manual and automatic the metron series mv600 high voltage fire pump controllers are a modular concept system, which utilize stateoftheart vacuum bottle technology. Application guide for electric fire pump controllers. A pump that is specified to the correct water pressure and flow a pump driver, either an electric motor or a diesel engine a fire pump controller for automatic operation of the pump driver a gear drive for transmitting power from the pump driver to the pump itself. Fire pump controller for electric motor driven fire pumps mv600 fire pump controller in nema 4 enclosure high voltage controllers series mv600.
638 294 191 1226 1493 780 962 74 1244 1240 1494 784 84 665 1074 376 487 1190 1491 1240 1492 132 1236 985 108 1059 1081 744 82 926 820